Advanced Search

Flooding of a warehouse for plant protection products

  • FRANCE
Located in an industrial park, a warehouse storing 1,300 tonnes of finished phytosanitary products was flooded following dike failure. The facility was operating with 8 employees and its warehousing activity spanned 3,600 m² with an average height of 7 m[...]
Read more

Flooding of an explosives manufacturing plant

  • FRANCE
A site manufacturing explosives was flooded following heavy rains. The products involved are not sensitive to water. A 15 hectare marshland located upstream to the site serves as an outfall for water overflowing from neighbouring lands. A 150 m³/h lift pump[...]
Read more

Flooding of a paper mill

  • FRANCE
The RHONE river overflowed due to heavy rains and flooded a paper mill located in an industrial area. This site produced kraft paper pulp from softwood bleached with oxygen, hydrogen peroxide and chlorine dioxide also stores black liquor, fuel oil, methanol,[...]
Read more

Cases of legionellosis, 18 of which were fatal

  • FRANCE
On November 28, 2003, two cases of Legionnaire's Disease were recorded, the first symptoms of which dated back to the beginning of November. The dates of outbreak of the pathology, which were then staggered over time, revealed two distinct waves[...]
Read more

Ammonia leak

  • FRANCE
At a steel factory, a small ammonia (NH3) leak was observed during the day on a tap valve fitting (inner tap diam.: 8 mm) of a pipe connecting storage tanks in the hydrogen production unit. This gas was being used[...]
Read more

Fire followed by an explosion in a warehouse

  • FRANCE
Fire-fighters battled for 45 min to contain the blaze at a 1,000-m² hangar belonging to a fruit farmer when a very powerful explosion rocked the building around 5 pm. The explosive mass involved was estimated at 300-500 kg of TNT.[...]
Read more

PCl3 overflow of an iso-container

  • FRANCE
A phosphorus trichloride (PCl3) leak occurred in a chemical plant during an iso container filling operation. The operator stopped the loading operation when the control room noticed a cloud of PCl3 and hydrogen chloride (HCl) being released into the atmosphere.[...]
Read more

Toxic release when degassing a container of PCl3

  • FRANCE
At a chemical plant, a large cloud of phosphorus trichloride (PCl3) and hydrogen chloride was released during a degassing test conducted on a PCl3 iso-container damaged during an incident that same morning (ARIA 26003). The plant's internal emergency plan was[...]
Read more

Explosion in a chemical plant

  • AUTRICHE
In a chemical plant, 2 explosions occurred in a glyoxylic acid production line followed by a fire. The building in question housed a production unit for intermediate chemicals used in manufacturing antibiotics and crop protection products. The fire-fighters brought the[...]
Read more

Spill of heavy fuel oil in an oil terminal

  • SUEDE
A spill of 328 metric tons of heavy fuel oil happened in an Oil Terminal during the discharge of the product from a ship vessel to a storage tank. At 10.30 p.m. the discharge to storage tank No 375 was[...]
Read more