Human error or organizational failure ?

In recent decades, companies have developed technical measures to improve the reliability of their installations over time and to prevent industrial risks. Safety management systems were then put in place to ensure the robustness of the whole. Progress has been[...]
Read more

Fire outbreak on a stripping unit inside a steel mill

  • FRANCE
Fire was detected at 10:05 pm in the stainless steel sheet stripping unit of an upper-tier Seveso metallurgical plant. The surface treatment line, composed of 7 unheated polypropylene tanks (5 containing hydrochloric acid, 1 containing hydrofluoric acid, 1 containing nitric[...]
Read more

Acrylic acid tank explosion and fire in a chemical plant

  • JAPON
During his shift, an employee of a special chemical products plant noticed at 1:20 pm a release of white smoke through the vents on an intermediate storage tank containing acrylic acid (AA, C3H4O2, flammable and corrosive substance, boiling point: 141°C).[...]
Read more

Breakage of a black liquor tank

  • FRANCE
At 2:30 pm inside a paper mill located 5 km east of Arcachon Bay, a 5,000-m³ black liquor tank ruptured. Black liquor is a highly alkaline paper manufacturing residue composed of organic matter, soda and other chemical products; it serves[...]
Read more

5.9-magnitude earthquake strucking industries

  • ITALIE
A 5.9-magnitude earthquake struck Emilia-Romagna at 4:03 am. The temblor lasted 30 seconds and damaged a range of structures, including dwellings, older buildings and industrial facilities: of the 7 deaths reported, 4 were working the night shift in warehouses and[...]
Read more

Accidental release of phosgene on a chemical platform

  • FRANCE
Around 10:30 pm in the isocyanate unit at a chemical plant, a sensor detected a rapid conductivity rise in a heat exchanger, in which phosgene (COCl2) pressurised to tens of bar was being reheated with water vapour at 28 bar before[...]
Read more

Triggering of the foam extinction system inside a chemicals firm

  • FRANCE
At 6:56 pm inside a warehouse for phytosanitary products assigned an upper-tier Seveso classification, the activation of a foam-based automatic extinction system installed in a 1,000-m² cell brought fire-fighters to the scene 44 min later. By the time responders arrived,[...]
Read more

Leak on a kerosene pipeline

  • ALLEMAGNE
A kerosene leak (A1 jet category) was detected on a pipeline (nominal diameter DN: 108, pressure: 13.8 bar, operational since: 1942) connecting a refinery to a storage area outside the oil platform site. The quantity of lost product was estimated[...]
Read more

Benzene leaks from a port petrochemical pipeline

  • FRANCE
Connecting an oil terminal to a chemical plant 1.5 km away, a heat-insulated pipeline pressurised at 300 mm was perforated following a period of intense cold weather; 4 m³ of benzene had solidified upon shrinking below 5°C. By 2:50 pm,[...]
Read more